Independent Pattern Tests
Doug's Test Results
|
Mr. Vang,
I hope these tables will give you some more insight as to what your modifications are capable of performing. I was truly lucky to be able to have gotten one of your modified barrels for my shotgun and I will at some time in the future be sending you my other barrel to modify. As soon as is possible I will be sending you the targets so that you can evaluate them for yourself.
YOURS,
Doug
|
|
|
The following tables show the various shot patterns for Remington, Winchester, Federal, PMC and Sellier & Bellot for the ranges of 25, 50 & 75 feet. As shot From, a Mossberg 590A1 with an 18.5 inch barrel. The tables 1, 2 & 3 show the patterns from the tightest to the widest in a descending order, while tables 2A & 3A show the % of hits from the most to the least in a descending order
|
|
TABLE A0 #1
|
MOSSBERG 590 A1 18.5 inch BARREL
|
|
25 FEET
|
|
|
MANUFACTURE 92S DATA
|
W X H IN INCHES
|
# OF PELLETS
|
|
FED-F132 L/E
|
2.75
|
3 X 4
|
9 OF 9
|
|
REM-SP12 00
|
2.75
|
3 X 6
|
9 OF 9
|
|
WIN-X1200
|
2.75
|
4 X 7
|
9 OF 9
|
|
FED-131 000
|
3
|
4 X 7
|
10 OF 10
|
|
FED-H132 L/R
|
2.75
|
5 X 5
|
9 OF 9
|
|
FED- P154 00
|
2.75
|
5 X 5
|
9 OF 9
|
|
FED-F127 00
|
2.75
|
5 X 6
|
9 OF 9
|
|
FED-F127 000
|
2.75
|
5 X 6
|
8 OF 8
|
|
REM-SP12 000
|
2.75
|
5 X 6
|
8 OF 8
|
|
FED-F130 00
|
2.75
|
5 X 8
|
12 OF 12
|
|
PMC-BSL120 L/R =
|
2.75
|
6 X5
|
9 OF 9
|
|
REM-SP12S MAG
|
2.75
|
6 X 7
|
12 OF 12
|
|
REM-SP12H MAG
|
3
|
6 X 7
|
15 OF 15
|
|
WIN-XB123 00
|
3
|
6 X 8
|
15 OF 15
|
|
PMC-BSH1200
|
2.75
|
7 X 7
|
9 OF 9
|
|
S & B
|
2.75
|
7 X 7
|
9 OF 9
|
|
FED-F131 00
|
3
|
8 X 6
|
15 OF 15
|
L/E= LAW ENFORCMENT TACTICAL
L/R=LOW / REDUCED RECOIL
PMC AND S & B ARE NOT BUFFERED LOADS
|
|
TABLE A0 #2
|
MOSSBERG 590 A1 18.5 inch BARREL
|
|
50 FEET
|
|
|
MANUFACTURE 92S DATA
|
W X H IN INCHES
|
# OF PELLETS
|
|
FED-P154 00
|
2.75
|
00
|
4 X 9
|
9 OF 9
|
|
WIN-X1200
|
2.75
|
00
|
6 X 6
|
7 OF 9
|
|
FED-H13200 L/R
|
2.75
|
00
|
6 X 6
|
9 OF 9
|
|
FED-F127 000
|
2.75
|
000
|
6 X 6
|
6 OF 8
|
|
REM-SP12 00
|
2.75
|
00
|
6 X 6
|
7 OF 9
|
|
FED-131 000
|
3
|
000
|
7 X 8
|
8 OF 10
|
|
FED-F127 00
|
2.75
|
00
|
8 X 5
|
8 OF 9
|
|
S & B
|
2.75
|
00
|
8 X 6
|
7 OF 9
|
|
FED-132 L/E
|
2.75
|
00
|
8 X 9
|
7 OF 9
|
|
PMC-BSL1200 L/R
|
2.75
|
00
|
8 X 9
|
7 OF 9
|
|
WIN- XB12300
|
3
|
00
|
8 X 9
|
10 OF 15
|
|
REM-SP12H MAG
|
3
|
00
|
8 X 10
|
12 OF 15
|
|
FED-F130 00
|
2.75
|
00
|
9 X 9
|
10 OF 12
|
|
FED-F131 00
|
3
|
00
|
9 X 11
|
7 OF 15
|
|
REM-SP12 000
|
2.75
|
00
|
10 X 6
|
8 OF 8
|
|
PMC-BSH1200
|
2.75
|
00
|
10 X 7
|
8 OF 9
|
|
REM-SP12S MAG
|
2.75
|
00
|
10 X 8
|
9 OF 12
|
|
TABLE A0 #2A
|
MOSSBERG 590 A1 18.5 inch BARREL
|
|
50 FEET
|
|
|
MANUFACTURE 92S DATA
|
W X H IN INCHES
|
# OF PELLETS
|
% OF HITS
|
|
FED-P154 00
|
2.75
|
00
|
4 X 9
|
9 OF 9
|
100
|
|
FED-H13200 L/R
|
2.75
|
00
|
6 X 9
|
9 OF 9
|
100
|
|
REM-SP12 000
|
2.75
|
000
|
10 X 6
|
9 OF 9
|
100
|
|
FED-F127 00
|
2.75
|
00
|
8 X 5
|
8 OF 9
|
88
|
|
PMC-BSH1200
|
2.75
|
00
|
10 X 7
|
8 OF 9
|
88
|
|
FED-F130 00
|
2.75
|
00
|
9 X 9
|
9 X 9
|
83
|
|
REM-SP12H MAG
|
3
|
00
|
8 X 10
|
8 X 10
|
80
|
|
FED-131 000
|
3
|
000
|
7 X 8
|
7 X 8
|
80
|
|
WIN-X1200
|
2.75
|
00
|
6 X 6
|
6 X 6
|
77
|
|
REM-SP12 00
|
2.75
|
00
|
6 X 9
|
6 X 9
|
77
|
|
S & B
|
2.75
|
00
|
8 X 6
|
7 OF 9
|
77
|
|
FED-132 L/E
|
2.75
|
00
|
8 X 9
|
7 OF 9
|
77
|
|
PMC-BSL120 L/R
|
2.75
|
00
|
8 X 9
|
7 OF 9
|
77
|
|
FED-F127000
|
2.75
|
000
|
6 X 9
|
6 OF 8
|
75
|
|
REM-SP12S MAG
|
2.75
|
00
|
10 X 8
|
9 OF 12
|
75
|
|
WIN-XB12300
|
3
|
00
|
8 X 9
|
10 OF 15
|
66
|
|
FED-F131 00
|
3
|
00
|
9 X 11
|
7 OF 15
|
46
|
|
TABLE A0 #3
|
MOSSBERG 590 A1 18.5 inch BARREL
|
|
75 FEET
|
|
|
MANUFACTURE 92S DATA
|
W X H IN INCHES
|
# OF PELLETS
|
|
REM-SP12 00
|
2.75
|
00
|
5 X 8
|
5 OF 9
|
|
FED-P154 00
|
2.75
|
00
|
6 X 3
|
5 OF 10
|
|
REM-SP12S MAG
|
2.75
|
00
|
6 X 9
|
6 OF 12
|
|
FED-H132 L/R
|
2.75
|
00
|
7 X 6
|
2 OF 9
|
|
PMC-BSH1200
|
2.75
|
000
|
7 X 8
|
6 OF 9
|
|
FED-F127 00
|
2.75
|
00
|
8 X 10
|
8 OF 9
|
|
REM-SP12 000
|
2.75
|
00
|
9 X 3
|
4 OF 8
|
|
WIN-X1200
|
2.75
|
00
|
9 X 7
|
4 OF 9
|
|
FED-F132 L/E
|
2.75
|
00
|
9 X 8
|
6 OF 9
|
|
PMC-BSL1200 L/R
|
2.75
|
00
|
9 X 9
|
7 OF 9
|
|
S & B
|
2.75
|
00
|
9 X 10
|
3 OF 9
|
|
FED-F130 00
|
2.75
|
00
|
10 X 10
|
10 OF 12
|
|
FED-F127 000
|
2.75
|
000
|
10 X 10
|
5 OF 8
|
|
FED-F131 00
|
3
|
00
|
10 X 12
|
9 OF 15
|
|
WIN-XB12300
|
3
|
00
|
11 X 8
|
10 OF 15
|
|
FED-F131 000
|
3
|
000
|
11 X 9
|
6 OF 10
|
|
REM-SP12H MAG
|
3
|
00
|
11 X 11
|
11 OF 15
|
|
TABLE A0 #3A
|
MOSSBERG 590 A1 18.5 inch BARREL
|
|
75 FEET
|
|
|
MANUFACTURE 92S DATA
|
W X H IN INCHES
|
# OF PELLETS
|
% OF HITS
|
|
FED-F127 00
|
2.75
|
00
|
8 X 10
|
8 OF 9
|
88
|
|
FED-F130 00
|
2.75
|
00
|
10 X 10
|
10 OF 12
|
83
|
|
PMC-BSL120 L/R
|
2.75
|
00
|
7 OF 9
|
7 OF 9
|
77
|
|
REM-SP12H MAG
|
3
|
00
|
11 X 11
|
11 OF 15
|
73
|
|
PMC-BSH1200
|
2.75
|
00
|
7 X 8
|
6 OF 9
|
66
|
|
FED-F132 L/E
|
2.75
|
00
|
9 X 8
|
6 OF 9
|
66
|
|
WIN-XB12300
|
3
|
00
|
11 X 8
|
10 OF 15
|
62
|
|
FED-F127 000
|
2.75
|
000
|
10 X 10
|
5 OF 8
|
66
|
|
FED-F131 00
|
3
|
00
|
10 X 12
|
9 OF 15
|
60
|
|
FED-F131 000
|
3
|
000
|
11 X 9
|
6 OF 10
|
60
|
|
REM-SP12 00
|
2.75
|
00
|
5 X 8
|
5 OF 9
|
55
|
|
FED-P154 00
|
2.75
|
00
|
6 X 3
|
5 OF 10
|
50
|
|
REM-SP12S MAG
|
2.75
|
00
|
6 X 9
|
6 OF 12
|
50
|
|
REM-SP12 000
|
2.75
|
000
|
9 X 3
|
4 OF 8
|
50
|
|
WIN-X1200
|
2.75
|
00
|
9 X 7
|
4 OF 9
|
44
|
|
S & B
|
2.75
|
00
|
9 X 10
|
3 OF 9
|
33
|
|
FED-H132 L/R
|
2.75
|
00
|
7 X 6
|
2 OF 9
|
22
|
|
A very special thanks to Doug for this excellent analysis! We at Vang Comp Systems really appreciate you sharing your results with us and know it will help others.
|
|
|
|
|